Title A Study on the Operational Status of the Chamber for Testing the Thermal Performance of Curtain Walls
Author Sang Tae No+
Institutions Department of Architectural Engineering, Korea National University of Transportation, Korea
Abstract The purposes of this study were to analyze criteria for measurement chamber design dedicated curtain wall, and how to measure of performance configuration and status of the chamber that is currently being used. Main dealing criteria is AAMA 1503-09. Measurement of data is made in curtain wall Mock-up experiment station with thermal imaging camera. Measurement data using thermal imaging cameras at Mock-up curtain was made at the test site. The results of this study were as follows; There is no U-value test method for actual size of curtain wall. The thermal test outdoor chamber showed heat loss in the connection part of indoor and outdoor chamber. And the indoor chamber showed unstable temperature distribution by height.
Keyword Curtain wall, U-value, Thermal chamber, Thermal test, Thermal performance standards
PP. PP.147~154